{"title":"Generator Cord","description":"","products":[{"product_id":"18-2c-flat-thhn-pvc-tray-cable","title":"#18-2C Flat THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25 ft. to maximum 1000 ft. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e18 AWG\u003cbr\u003e\u003cstrong\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e2\u003cbr\u003e\u003cstrong\u003eAmps:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e6.0\u003cbr\u003e\u003cstrong\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e7\/.0152\u003cbr\u003e\u003cstrong\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e0.51 mm \/ 0.020 inches\u003cbr\u003e\u003cstrong\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cstrong\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e0.176 x 0.262 inches\u003cbr\u003e\u003cstrong\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e0.041 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341298639131,"sku":"#GCW621","price":0.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p1_b51a23ed-11f3-49f0-b7e1-5e93311382f3.webp?v=1755721340"},{"product_id":"18-3c-thhn-pvc-tray-cable","title":"#18-3C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 5000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e18 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3\u003cbr\u003e\u003cb\u003eAmps:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e6.0\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0152\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.51 mm \/ 0.020 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7.24 mm \/ 0.285 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.015 lbs per ft\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.046 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341299654939,"sku":"#GCW622","price":0.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p2_aef25042-31a8-4a40-bd24-10d9163e174c.webp?v=1757095830"},{"product_id":"18-4c-thhn-pvc-tray-cable","title":"#18-4C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 5000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e18 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e4\u003cbr\u003e\u003cb\u003eAmps:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e4.8\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0152\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.51 mm \/ 0.020 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7.87 mm \/ 0.310 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.020 lbs per ft\u003cbr\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.054 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341301653787,"sku":"#GCW623","price":0.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p3_d7c316d7-5ef9-49f5-843c-56268a2dfd9d.webp?v=1757095829"},{"product_id":"18-5c-thhn-pvc-tray-cable","title":"#18-5C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e18 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e5\u003cbr\u003e\u003cstrong\u003eAmps:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4.8\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0152\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.51 mm \/ 0.020 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e8.51 mm \/ 0.335 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.026 lbs per ft\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.065 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341302604059,"sku":"#GCW624","price":0.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p4_b21bb830-d2e1-41e2-bab5-2f45ce22a7c0.webp?v=1757095828"},{"product_id":"18-7c-thhn-pvc-tray-cable","title":"#18-7C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 5000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w Black Stripe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e18 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0152\u003cbr\u003e\u003cstrong\u003eAmps:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4.2\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.51 mm \/ 0.020 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e9.14 mm \/ 0.360 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.036 lbs per ft\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.082 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341303062811,"sku":"#GCW625","price":0.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p5_57f95861-9b03-413d-90ed-8c04cf578985.webp?v=1757095826"},{"product_id":"18-9c-thhn-pvc-tray-cable","title":"#18-9C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w\/ Black stripe, Blue w\/ Black stripe, Orange w\/ Black stripe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e18 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e9\u003cbr\u003e\u003cstrong\u003eAmps:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4.2\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0192\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.015 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.408 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.072 lbs per ft\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.105 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341306863899,"sku":"#GCW626","price":1.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p6_4a485fef-e8db-4bd1-9c6c-f71d98ffa97c.webp?v=1757095825"},{"product_id":"18-12c-thhn-pvc-tray-cable","title":"#18-12C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003eUL Type TC-ER\u003c\/strong\u003e\u003cstrong\u003e, PVC\/Nylon\/PVC, Control, Unshielded, 600V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w\/ Black Stripe, Blue w\/ Black Stripe, Orange w\/ Black Stripe, Yellow w\/ Black Stripe, Brown w\/ Black Stripe, Black w\/ Red Stripe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e18 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e12\u003cbr\u003e\u003cb\u003eAmps:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3.0\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.086\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.51 mm \/ 0.020 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.143 mm \/ 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e11.455 mm \/ 0.451 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.036 lbs per ft\u003cbr\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.156 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341308535067,"sku":"#GCW627","price":1.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p7_6783c075-02d7-4c81-99b5-d98a6f4cc9b1.webp?v=1757095824"},{"product_id":"18-15c-thhn-pvc-tray-cable","title":"#18-15C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003eUL Type TC-ER\u003c\/strong\u003e\u003cstrong\u003e, PVC\/Nylon\/PVC, Control, Unshielded, 600V, \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w Black Stripe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e18 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e15\u003cbr\u003e\u003cstrong\u003eAmps:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3.0\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.507 inches\u003cbr\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.169 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341312205083,"sku":"#GCW628","price":1.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p8_c641724d-36e9-4ad7-9c90-c57b4ecf76cd.webp?v=1757095823"},{"product_id":"18-19c-thhn-pvc-tray-cable","title":"#18-19C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003eUL Type TC-ER\u003c\/strong\u003e\u003cstrong\u003e, PVC\/Nylon\/PVC, Control, Unshielded, 600V, \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 5000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 Standard.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w\/ Blk, Blue w\/ Blk, Orange w\/ Blk, Yellow w\/ Blk, Brown w\/ Blk, Black w\/ Red, Blue w\/ Red, Orange w\/ Red, Yellow w\/ Red, Brown w\/ Red, Black w\/ Blue, Red w\/ Blue, Orange w\/ Blue\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e18 AWG\u003cbr\u003e\u003cstrong\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e19\u003cbr\u003e\u003cstrong\u003eAmps:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3.0\u003cbr\u003e\u003cstrong\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e7\/.0152\u003cbr\u003e\u003cstrong\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e0.381 mm \/ 0.015 inches\u003cbr\u003e\u003cstrong\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e1.524 mm \/ 0.060 inches\u003cbr\u003e\u003cstrong\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e11.87 mm \/ 0.640 inches\u003cbr\u003e\u003cstrong\u003eWeight:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e0.220 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341315154203,"sku":"#GCW629","price":2.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p9_1c4cf178-7659-4d9b-bd99-f77a8172874e.webp?v=1757095822"},{"product_id":"18-25c-thhn-pvc-tray-cable","title":"#18-25C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003eUL Type TC-ER\u003c\/strong\u003e\u003cstrong\u003e, PVC\/Nylon\/PVC, Control, Unshielded, 600V, \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w Black Stripe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e18 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e25\u003cbr\u003e\u003cstrong\u003eAmps:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e2.7\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003c\/b\u003e 0.06 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.66 inches\u003cbr\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.258 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341315875099,"sku":"#GCW630","price":3.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p10_ab14e2fd-31b1-4167-b5d1-9a45691e0bf9.webp?v=1757095821"},{"product_id":"18-37c-thhn-pvc-tray-cable","title":"#18-37C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003eUL Type TC-ER\u003c\/strong\u003e\u003cstrong\u003e, PVC\/Nylon\/PVC, Control, Unshielded, 600V, \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e18 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e37\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003c\/b\u003e 0.06 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.745 inches\u003cbr\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.382 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341319872795,"sku":"#GCW631","price":3.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p11_472b1796-e545-46e5-a951-b48ba2c7524b.webp?v=1757095820"},{"product_id":"16-2c-thhn-pvc-tray-cable","title":"#16-2C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Flat 2C, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 5000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e16 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e2\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0192\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.51 mm \/ 0.020 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7.62 mm \/ 0.300 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.020 lbs per ft\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.045 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341321150747,"sku":"#GCW632","price":0.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p12_b775f798-f7db-4987-a21c-29c24edfb462.webp?v=1757095819"},{"product_id":"16-3c-thhn-pvc-tray-cable","title":"#16-3C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003e\n\u003cp\u003e\u003cstrong\u003e16\/3 THHN-PVC Tray Cable Specifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/caption\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Strand:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\/.0192\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum AVG Insulation Thickness:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.51 mm \/ 0.020 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum AVG Jacket Thickness:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.14 mm \/ 0.045 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutside Diameter:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.00 mm \/ 0.315 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCopper Weight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.024 lbs per ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.060 lbs per ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341322690843,"sku":"#GCW633","price":0.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p13_344a0e69-fe59-458f-aacc-206db2f19019.webp?v=1757095818"},{"product_id":"16-4c-thhn-pvc-tray-cable","title":"#16-4C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e16 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e4\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0192\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.51 mm \/ 0.020 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e8.64 mm \/ 0.340 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.032 lbs per ft\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.074 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341326524699,"sku":"#GCW634","price":0.63,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p14_e2594571-6a3e-48b8-9d5b-ab692222360b.webp?v=1757095816"},{"product_id":"16-5c-thhn-pvc-tray-cable","title":"#16-5C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003e\n\u003cp\u003e\u003cstrong\u003e16-5C THHN-PVC Tray Cable Specifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/caption\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Strand:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\/.0192\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.51 mm \/ 0.020 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1.14 mm \/ 0.045 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOutside Diameter:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e9.40 mm \/ 0.370 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCopper Weight:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.040 lbs per ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eNet Weight:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.097 lbs per ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341327343899,"sku":"#GCW635","price":0.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p15_f09061e9-3523-4810-badd-aec924ca7865.webp?v=1757095815"},{"product_id":"16-6c-thhn-pvc-tray-cable","title":"#16-6C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 75' to maximum 2500'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e16 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e6\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0192\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.38 mm \/ 0.015 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e9.90 mm \/ 0.390 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.040 lbs per ft\u003cbr\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.109 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341329506587,"sku":"#GCW636","price":1.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p16_94ca0835-82c6-4b5e-adfe-3a5064708f0d.webp?v=1757095814"},{"product_id":"16-7c-thhn-pvc-tray-cable","title":"#16-7C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w Black Stripe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e16 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0192\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.51 mm \/ 0.020 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e10.16 mm \/ 0.400 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.056 lbs per ft\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.111 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341334487323,"sku":"#GCW637","price":1.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p17_a05214c5-719d-47cc-8ac9-d099c66b28e2.webp?v=1757095813"},{"product_id":"16-9c-thhn-pvc-tray-cable","title":"#16-9C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w\/ Black stripe, Blue w\/ Black stripe, Orange w\/ Black stripe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e16 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e9\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0192\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.51 mm \/ 0.020 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e11.68 mm \/ 0.460 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.072 lbs per ft\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.141 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341335503131,"sku":"#GCW638","price":1.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p18_4bf37689-e866-43bf-a828-d4f1d2d0b3d9.webp?v=1757095812"},{"product_id":"16-10c-thhn-pvc-tray-cable","title":"#16-10C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w\/ Black stripe, Blue w\/ Black stripe, Orange w\/ Black stripe, Yellow w\/ Black Stripe\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cstrong\u003eSize: \u003c\/strong\u003e16 AWG\u003cbr\u003e\u003cstrong\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e10\u003cbr\u003e\u003cstrong\u003eConductor Strand: \u003c\/strong\u003e7\/.0192\u003cbr\u003e\u003cstrong\u003eMinimum AVG Jacket Thickness: \u003c\/strong\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cstrong\u003eOutside Diameter: \u003c\/strong\u003e12.19 mm \/ 0.480 inches\u003cbr\u003e\u003cstrong\u003eNet Weight: \u003c\/strong\u003e0.157 lbs per ft\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341338583323,"sku":"#GCW639","price":1.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p19_0e7590a2-fd28-46f1-a084-fe5a23733eaf.webp?v=1757095811"},{"product_id":"16-12c-thhn-pvc-tray-cable","title":"#16-12C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003eUL Type TC-ER\u003c\/strong\u003e\u003cstrong\u003e, PVC\/Nylon\/PVC, Control, Unshielded, 600V, \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w Black Stripe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e16 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e12\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0152\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e 0.015 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003c\/b\u003e 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.535 inches\u003cbr\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.188 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341341040923,"sku":"#GCW640","price":1.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p20_5f9750e6-588c-46e0-b1f4-4f95d5eb0e7f.webp?v=1757095810"},{"product_id":"16-15c-thhn-pvc-tray-cable","title":"#16-15C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003eUL Type TC-ER\u003c\/strong\u003e\u003cstrong\u003e, PVC\/Nylon\/PVC, Control, Unshielded, 600V, \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w Black Stripe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e16 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e15\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0152\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e 0.015 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003c\/b\u003e 0.060 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.589 inches\u003cbr\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.235 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341341729051,"sku":"#GCW641","price":2.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p21_80734707-ba07-409d-ab58-cd25396c6982.webp?v=1757095809"},{"product_id":"16-19c-thhn-pvc-tray-cable","title":"#16-19C THHN-PVC Tray Cable","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUL Type TC-ER\u003c\/strong\u003e\u003cstrong\u003e, PVC\/Nylon\/PVC, Control, Unshielded, 600V, \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w Black Stripe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e16 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e19\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0152\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e 0.015 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003c\/b\u003e 0.060 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.619 inches\u003cbr\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.284 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341343924507,"sku":"#GCW642","price":3.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p22_64315065-7f1d-48e4-bad7-9b88e7edc39b.webp?v=1757095808"},{"product_id":"16-25c-thhn-pvc-tray-cable","title":"#16-25C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003eUL Type TC-ER\u003c\/strong\u003e\u003cstrong\u003e, PVC\/Nylon\/PVC, Control, Unshielded, 600V, \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w Black Stripe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e16 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e25\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0152\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.723 inches\u003cbr\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.376 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341344743707,"sku":"#GCW643","price":4.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p23_4264e44d-9e1b-4fac-bff6-f8b81a1926c4.webp?v=1757095807"},{"product_id":"16-30c-thhn-pvc-tray-cable","title":"#16-30C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003eUL Type TC-ER\u003c\/strong\u003e\u003cstrong\u003e, PVC\/Nylon\/PVC, Control, Unshielded, 600V, \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w Black Stripe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e16 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e30\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003c\/b\u003e 0.060 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.775 inches\u003cbr\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.456 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341345202459,"sku":"#GCW644","price":5.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p24_28916d88-042e-45e6-acd1-4e162a3987ac.webp?v=1757095806"},{"product_id":"16-50c-thhn-pvc-tray-cable","title":"#16-50C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003eUL Type TC-ER\u003c\/strong\u003e\u003cstrong\u003e, PVC\/Nylon\/PVC, Control, Unshielded, 600V, \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"color: #666666; font-family: Arial, Helvetica, sans-serif;\"\u003e\u003cspan\u003eE2 Color Code\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e16 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e50\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.980 inches\u003cbr\u003e\u003cstrong\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e0.689 lbs per ft\u003cbr\u003e \u003c\/p\u003e\n\u003cp class=\"specs\"\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341346152731,"sku":"#GCW645","price":7.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p25_5d3e5687-2de2-452f-a562-a6c9cb60d793.webp?v=1757095805"},{"product_id":"14-2c-thhn-pvc-tray-cable","title":"#14-2C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Flat 2C, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 10,000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eFully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e14 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e2\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0242\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.51 mm \/ 0.020 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e8.13 mm \/ 0.320 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.026 lbs per ft\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.064 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341348643099,"sku":"#GCW646","price":0.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p26_8d315e3b-c4a8-4e91-8ce7-608dbf4251d5.webp?v=1757095804"},{"product_id":"14-3c-thhn-pvc-tray-cable","title":"#14-3C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eFully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e14 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0242\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.51 mm \/ 0.020 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e8.76 mm \/ 0.345 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.039 lbs per ft\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.080 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341352837403,"sku":"#GCW647","price":0.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p27_187359d8-2f9e-4e02-81d4-cd009acfdd52.webp?v=1757095803"},{"product_id":"14-4c-thhn-pvc-tray-cable","title":"#14-4C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eFully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003e\n\u003cp\u003e\u003cstrong\u003e14\/4 THHN-PVC Tray Cable Specifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/caption\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Strand:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\/.0242\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum AVG Insulation Thickness:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.51 mm \/ 0.020 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum AVG Jacket Thickness:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.14 mm \/ 0.045 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutside Diameter:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.27 mm \/ 0.365 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCopper Weight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.052 lbs per ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.100 lbs per ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341356212507,"sku":"#GCW648","price":0.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p28_6ba04525-ec82-47ec-8d4a-90903c7aa028.webp?v=1757095802"},{"product_id":"14-5c-thhn-pvc-tray-cable","title":"#14-5C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 5000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eFully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e14 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e5\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0242\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.51 mm \/ 0.020 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e10.41 mm \/ 0.410 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.065 lbs per ft\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.118 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341357621531,"sku":"#GCW649","price":1.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p29_7e7e5a24-b88e-4260-a868-feba9f456a10.webp?v=1757095800"},{"product_id":"14-7c-thhn-pvc-tray-cable","title":"#14-7C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eFully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w Black Stripe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e14 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0242\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.51 mm \/ 0.020 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e11.30 mm \/ 0.445 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.090 lbs per ft\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.153 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341358735643,"sku":"#GCW650","price":1.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p30_afe8451b-e75a-4e27-9499-acb64a742094.webp?v=1755721310"},{"product_id":"14-9c-thhn-pvc-tray-cable","title":"#14-9C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eFully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w\/ Black stripe, Blue w\/ Black stripe, Orange w\/ Black stripe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e14 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e9\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0242\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.51 mm \/ 0.020 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.52 mm \/ 0.060 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e12.83 mm \/ 0.505 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.116 lbs per ft\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.213 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341360636187,"sku":"#GCW651","price":2.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p31_a41f9ef6-b965-465b-8705-a8c1c6933433.webp?v=1757095799"},{"product_id":"14-12c-thhn-pvc-tray-cable","title":"#14-12C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003eUL Type TC-ER\u003c\/strong\u003e\u003cstrong\u003e, PVC\/Nylon\/PVC, Control, Unshielded, 600V, \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 3000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w Black Stripe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e14 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e12\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0152\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e 0.015 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003c\/b\u003e 0.060 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.590 inches\u003cbr\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.270 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341361193243,"sku":"#GCW652","price":2.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p32_d83e189c-808e-48d8-8ac3-04ba322e9a2e.webp?v=1757095798"},{"product_id":"14-15c-thhn-pvc-tray-cable","title":"#14-15C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003eUL Type TC-ER\u003c\/strong\u003e\u003cstrong\u003e, PVC\/Nylon\/PVC, Control, Unshielded, 600V, \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 4000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w Black Stripe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e14 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e15\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0152\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e 0.015 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003c\/b\u003e 0.060 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.652 inches\u003cbr\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.328 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341363421467,"sku":"#GCW653","price":3.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p33_9796beee-ffcb-433a-a69d-cbf5115638c1.webp?v=1757095797"},{"product_id":"14-19c-thhn-pvc-tray-cable","title":"#14-19C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003eUL Type TC-ER\u003c\/strong\u003e\u003cstrong\u003e, PVC\/Nylon\/PVC, Control, Unshielded, 600V, \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w\/ Black, Blue w\/ Black, Orange w\/ Black, Yellow w\/ Black, Brown w\/ Black, Black w\/ Red, Blue w\/ Red, Orange w\/ Red, Yellow w\/ Red, Brown w\/ Red, Black w\/ Blue, Red w\/ Blue, Orange w\/ Blue\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e14 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e19\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0242\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e 0.020 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003c\/b\u003e 0.060 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.695 inches\u003cbr\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.396 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341364306203,"sku":"#GCW654","price":3.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p34_7df76264-28d7-405b-844e-63af0be066c6.webp?v=1757095796"},{"product_id":"14-25c-thhn-pvc-tray-cable","title":"#14-25C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003eUL Type TC-ER\u003c\/strong\u003e\u003cstrong\u003e, PVC\/Nylon\/PVC, Control, Unshielded, 600V, \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w Black Stripe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e14 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e25\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0152\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.838 inches\u003cbr\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.520 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341364633883,"sku":"#GCW655","price":5.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p35_2502e9cf-d537-4d1d-af0c-7c31e7d81099.webp?v=1757095795"},{"product_id":"14-30c-thhn-pvc-tray-cable","title":"#14-30C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003eUL Type TC-ER\u003c\/strong\u003e\u003cstrong\u003e, PVC\/Nylon\/PVC, Control, Unshielded, 600V, \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 500'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red\/Black, Blue\/Black, Orange\/Black, Yellow\/Black, Brown\/Black, Black\/Red, Blue\/Red, Orange\/Red, Yellow\/Red, Brown\/Red, Black\/Blue, Red\/Blue, Orange\/Blue, Yellow\/Blue, Brown\/Blue, Black\/Orange, Red\/Orange, Blue\/Orange, Yellow\/Orange, Brown\/Orange, Black\/Yellow, Red\/Yellow, Blue\/Yellow, Orange\/Yellow\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e14 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e30\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0152\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.886 in \/ 22.51 mm\u003cbr\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.638 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341365649691,"sku":"#GCW656","price":7.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p36_1a1187ba-ce97-49fb-93cb-4ad2858629a0.webp?v=1757095794"},{"product_id":"14-37c-thhn-pvc-tray-cable","title":"#14-37C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003eUL Type TC-ER\u003c\/strong\u003e\u003cstrong\u003e, PVC\/Nylon\/PVC, Control, Unshielded, 600V, \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"color: #666666; font-family: Arial, Helvetica, sans-serif;\"\u003e\u003cspan\u003eE2 Color Code\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e14 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e37\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.968 inches\u003cbr\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.794 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341374071067,"sku":"#GCW657","price":8.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p37_d3051b62-e590-436d-8851-e87bf92a27ec.webp?v=1757095793"},{"product_id":"14-50c-thhn-pvc-tray-cable","title":"#14-50C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003eUL Type TC-ER\u003c\/strong\u003e\u003cstrong\u003e, PVC\/Nylon\/PVC, Control, Unshielded, 600V, \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"color: #666666; font-family: Arial, Helvetica, sans-serif;\"\u003e\u003cspan\u003eE2 Color Code\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e14 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e50\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.03 inches\u003cbr\u003e\u003cstrong\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e1.013 lbs per ft\u003cbr\u003e \u003c\/p\u003e\n\u003cp class=\"specs\"\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341378887963,"sku":"#GCW658","price":12.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p38_16c02eab-b716-4785-8172-b86c306446f1.webp?v=1757095792"},{"product_id":"12-2c-thhn-pvc-tray-cable","title":"#12-2C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Flat 2C, Control,  Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 5000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eFully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e12 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e2\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0305\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.51 mm \/ 0.020 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e9.02 mm \/ 0.355 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.041 lbs per ft\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.085 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341379674395,"sku":"#GCW659","price":0.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p39_01ec75d1-01e0-4bed-81de-f78e74188e84.webp?v=1755721301"},{"product_id":"12-3c-thhn-pvc-tray-cable","title":"#12-3C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eFully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e12 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0305\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.51 mm \/ 0.020 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e9.78 mm \/ 0.385 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.062 lbs per ft\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.131 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341388751131,"sku":"#GCW660","price":0.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p40_34d019b9-7574-4404-93c4-5100d8c74182.webp?v=1757095791"},{"product_id":"12-3c-thhn-pvc-tray-cable-black-white-green","title":"#12-3C THHN-PVC Tray Cable (Black, White, Green)","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eFully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003eBlack, White, Green\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cstrong\u003eSize: \u003c\/strong\u003e12 AWG\u003cbr\u003e\u003cstrong\u003eNumber of Conductors: \u003c\/strong\u003e3\u003cbr\u003e\u003cstrong\u003eConductor Strand: \u003c\/strong\u003e7\/.0305\u003cbr\u003e\u003cstrong\u003eMinimum AVG Insulation Thickness: \u003c\/strong\u003e0.51 mm \/ 0.020 inches\u003cbr\u003e\u003cstrong\u003eMinimum AVG Jacket Thickness: \u003c\/strong\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cstrong\u003eOutside Diameter: \u003c\/strong\u003e9.78 mm \/ 0.385 inches\u003cbr\u003e\u003cstrong\u003eCopper Weight: \u003c\/strong\u003e0.062 lbs per ft\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNet Weight: \u003c\/strong\u003e0.131 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341389635867,"sku":"#GCW661","price":1.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p41_11e37c42-7daa-4536-acb0-2712dd19fb48.webp?v=1724804960"},{"product_id":"12-4c-thhn-pvc-tray-cable","title":"#12-4C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1500'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eFully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e12 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e4\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0305\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.51 mm \/ 0.020 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e10.67 mm \/ 0.420 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.083 lbs per ft\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.138 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341403332891,"sku":"#GCW662","price":1.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p42_943cb3b8-c12b-45e8-9f41-3b7426e97cc8.webp?v=1757095790"},{"product_id":"12-5c-thhn-pvc-tray-cable","title":"#12-5C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 10,000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eFully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e12 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e5\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0305\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.51 mm \/ 0.020 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e11.30 mm \/ 0.445 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.108 lbs per ft\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.165 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341406249243,"sku":"#GCW663","price":1.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p43_3044fb40-d777-4806-afd7-99236d2f2682.webp?v=1757095789"},{"product_id":"12-7c-thhn-pvc-tray-cable","title":"#12-7C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eFully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w Black Stripe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e12 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0305\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.51 mm \/ 0.020 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e12.45 mm \/ 0.490 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.144 lbs per ft\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.217 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341406937371,"sku":"#GCW664","price":2.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p44_907c16c0-cf9d-4f8b-a4ac-069b78f57fdf.webp?v=1757095788"},{"product_id":"12-9c-thhn-pvc-tray-cable","title":"#12-9C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eFully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w Black Stripe, Blue w Black Stripe, Orange w Black Stripe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e12 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e9\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0305\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.51 mm \/ 0.020 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.52 mm \/ 0.060 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e15.37 mm \/ 0.605 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.185 lbs per ft\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.297 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341416505627,"sku":"#GCW665","price":2.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p45_41a6d6aa-41e3-45ca-ba05-741babc5d96c.webp?v=1757095787"},{"product_id":"12-12c-thhn-pvc-tray-cable","title":"#12-12C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003eUL Type TC-ER\u003c\/strong\u003e\u003cstrong\u003e, PVC\/Nylon\/PVC, Control, Unshielded, 600V, \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w Black Stripe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e12 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e12\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0152\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e 0.015 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003c\/b\u003e 0.060 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.680 inches\u003cbr\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.388 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341421453595,"sku":"#GCW666","price":4.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p46_2d7f4d22-d166-4a17-bef5-419ac4783830.webp?v=1757095786"},{"product_id":"12-15c-thhn-pvc-tray-cable","title":"#12-15C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003eUL Type TC-ER\u003c\/strong\u003e\u003cstrong\u003e, PVC\/Nylon\/PVC, Control, Unshielded, 600V, \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w Black Stripe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e12 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e15\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0152\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e 0.015 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003c\/b\u003e 0.060 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.754 inches\u003cbr\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.475 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341425418523,"sku":"#GCW667","price":4.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p47_b63a2a91-fb21-40ad-a63a-d8e9a77d4c2e.webp?v=1724805448"},{"product_id":"12-19c-thhn-pvc-tray-cable","title":"#12-19C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003eUL Type TC-ER\u003c\/strong\u003e\u003cstrong\u003e, PVC\/Nylon\/PVC, Control, Unshielded, 600V, \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e18 AWG and 16 AWG fully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue, Orange, Yellow, Brown, Red w Black Stripe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e12 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e19\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0152\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e 0.015 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003c\/b\u003e 0.060 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.834 inches\u003cbr\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.619 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341443211547,"sku":"#GCW668","price":6.52,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p47_ec01500a-c2e1-4433-85a0-403be0c252a7.webp?v=1757095785"},{"product_id":"10-2c-flat-thhn-pvc-tray-cable","title":"#10-2C Flat THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Flat Cable, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eFully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e10 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e2 Flat\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0385\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.66 mm \/ 0.026 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e6.6 x 10.8 mm \/ 0.260 x 0.425 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.112 lbs per ft\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.191 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341451862299,"sku":"#GCW669","price":1.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p48_b63e97d1-6f72-4ca8-81a5-c64b0b08bb54.webp?v=1757095784"},{"product_id":"10-3c-thhn-pvc-tray-cable","title":"#10-3C THHN-PVC Tray Cable","description":"\u003cp\u003e\u003cstrong\u003ePVC\/Nylon\/PVC, Control, Unshielded, 600V, UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIn free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003eraceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eRated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003eIndustry Compliances:\u003cbr\u003e- UL 66 NEC Type TFN conductors\u003cbr\u003e- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e- UL 1581\u003cbr\u003e- ICEA S-95-658\u003cbr\u003eFlame Test Compliances:\u003cbr\u003e- UL 1277\u003cbr\u003e- IEEE 383\u003cbr\u003e- IEEE 1202\u003cbr\u003e- CSA FT4\u003cbr\u003eOther Compliances:\u003cbr\u003e- EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e- OSHA Acceptable\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eFully annealed stranded bare copper to ASTM B3\u003cbr\u003eClass B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)\u003cbr\u003eColor-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003eLead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack, Red, Blue\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e10 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3\u003cbr\u003e\u003cb\u003eConductor Strand:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7\/.0385\u003cbr\u003e\u003cb\u003eMinimum AVG Insulation Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.66 mm \/ 0.026 inches\u003cbr\u003e\u003cb\u003eMinimum AVG Jacket Thickness:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.14 mm \/ 0.045 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e11.43 mm \/ 0.450 inches\u003cbr\u003e\u003cb\u003eCopper Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.131 lbs per ft\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNet Weight:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.191 lbs per ft\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":49341454156059,"sku":"#GCW670","price":1.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/p49_acf6c578-7988-4191-8061-c1be4ad99cf3.webp?v=1757095783"}],"url":"https:\/\/www.globalcablewire.com\/collections\/generator-cord.oembed?page=8","provider":"Global Cable and Wire","version":"1.0","type":"link"}