{"title":"Copper SEU Wire","description":"\u003cp\u003e\u003cspan\u003eDesigned to carry current from the utility service point to the main electrical panel, SEU cable delivers reliable performance, ease of installation, and major cost savings compared to copper alternatives.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"4-4-6-copper-service-entrance-cable-seu","title":"4-4-6 Copper Service Entrance Cable SEU","description":"\u003cp data-path-to-node=\"2\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box. Minimum 25' to maximum 1000'.\u003c\/p\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cb data-path-to-node=\"3\" data-index-in-node=\"0\"\u003eApplications:\u003c\/b\u003e Type SE, Style SEU Service Entrance Cable is a round and flat cable used in all instances where service entrance cables are allowed. It is most often used to connect utility power to the meter base. This cable is suitable for wet and dry locations with temperatures not exceeding 90°C. The voltage rating of the electrical cable is 600 volts. \u003ci data-path-to-node=\"3\" data-index-in-node=\"357\"\u003eAlso known as: Copper SEU Service Entrance Cable, SEU Cable, SEU Service Cable, Copper Service Cable, Unarmored Service Entrance Cable.\u003c\/i\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003e\u003cb data-path-to-node=\"4\" data-index-in-node=\"0\"\u003eConductor:\u003c\/b\u003e Annealed soft copper conductors.\u003c\/p\u003e\n\u003cp data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eInsulated Phase Conductors (2 Conductors):\u003c\/b\u003e 7-strand annealed soft copper equipped with cross-linked polyethylene (XLPE) Type XHHW-2 insulation. Rated for up to 90°C in wet or dry locations.\u003c\/p\u003e\n\u003cp data-path-to-node=\"6\"\u003e\u003cb data-path-to-node=\"6\" data-index-in-node=\"0\"\u003eEquipment Ground Conductor:\u003c\/b\u003e 12-strand bare soft copper, applied as a concentric neutral ground around the insulated phase conductors.\u003c\/p\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cb data-path-to-node=\"7\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Gray, sunlight-resistant polyvinyl chloride (PVC) jacket. This dielectrically strong outer layer is highly resistant to corrosion, abrasion, chemicals, and mechanical impact.\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eStandards:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003eASTM - All applicable standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003eUL Standard 44 for XHHW-2 conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003eUL Standard 83 for THHN\/THWN conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003eUL Standard 854 Service Entrance Cables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003eFederal Specification A-A-59544\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003eNFPA 70: National Electrical Code (2011 Edition)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003eRoHS \/ REACH Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"10\"\u003e\u003ci data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eSpecifications:\u003c\/i\u003e*\u003c\/p\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eSize AWG:\u003c\/b\u003e 4-4-6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Annealed Soft Copper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eInsulation Material:\u003c\/b\u003e XLPE (Type XHHW-2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eOutside Diameter:\u003c\/b\u003e 0.790 x 0.481 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-path-to-node=\"11,4,0\" data-index-in-node=\"0\"\u003eAllowable Ampacity:\u003c\/b\u003e 95 Amps @ 90°C (100 Amps for Dwelling)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,5,0\"\u003e\u003cb data-path-to-node=\"11,5,0\" data-index-in-node=\"0\"\u003eNet Weight:\u003c\/b\u003e 0.42 lbs\/ft (420 lbs per 1,000 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003ci data-path-to-node=\"12\" data-index-in-node=\"0\"\u003e*Data provided on this page is subject to change based on different manufacturers' variances.\u003cbr\u003e\u003cbr\u003e *IImages are for reference only.\u003cbr\u003e\u003c\/i\u003e\u003c\/p\u003e","brand":"Global Cable and Wire","offers":[{"title":"Default Title","offer_id":52128022069531,"sku":"GCW1339","price":5.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/ChatGPTImage27abr2026_19_33_24.png?v=1777336416"},{"product_id":"6-6-8-copper-service-entrance-cable-seu","title":"6-6-8 Copper Service Entrance Cable SEU","description":"\u003cp data-path-to-node=\"2\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box. Minimum 25' to maximum 1000'.\u003c\/p\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cb data-path-to-node=\"3\" data-index-in-node=\"0\"\u003eApplications:\u003c\/b\u003e Type SE, Style SEU Service Entrance Cable is a round and flat electrical cable used in all instances where service entrance cables are allowed. It is most often used to connect utility power to the meter base. This cable is suitable for wet and dry locations with temperatures not exceeding 90°C. The voltage rating of the electrical cable is 600 volts. \u003ci data-path-to-node=\"3\" data-index-in-node=\"368\"\u003eAlso known as: Copper SEU Service Entrance Cable, SEU Cable, SEU Service Cable, Copper Service Cable, Unarmored Service Entrance Cable.\u003c\/i\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003e\u003cb data-path-to-node=\"4\" data-index-in-node=\"0\"\u003eConductor:\u003c\/b\u003e Annealed soft copper conductors.\u003c\/p\u003e\n\u003cp data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eInsulated Phase Conductors (2 Conductors):\u003c\/b\u003e 6 AWG, 7-strand annealed soft copper equipped with cross-linked polyethylene (XLPE) Type XHHW-2 insulation. Rated for up to 90°C in wet or dry locations.\u003c\/p\u003e\n\u003cp data-path-to-node=\"6\"\u003e\u003cb data-path-to-node=\"6\" data-index-in-node=\"0\"\u003eEquipment Ground Conductor:\u003c\/b\u003e 8 AWG, 8-strand bare soft copper, applied as a concentric neutral ground around the insulated phase conductors.\u003c\/p\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cb data-path-to-node=\"7\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Gray, sunlight-resistant polyvinyl chloride (PVC) jacket. This dielectrically strong outer layer is highly resistant to corrosion, abrasion, chemicals, and mechanical impact.\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eStandards:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003eASTM - All applicable standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003eUL Standard 44 for XHHW-2 conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003eUL Standard 83 for THHN\/THWN conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003eUL Standard 854 Service Entrance Cables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003eFederal Specification A-A-59544\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003eNFPA 70: National Electrical Code (2011 Edition)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003eRoHS \/ REACH Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"10\"\u003e\u003ci data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eSpecifications:\u003c\/i\u003e*\u003c\/p\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eSize AWG:\u003c\/b\u003e 6-6-8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Annealed Soft Copper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eInsulation Material:\u003c\/b\u003e XLPE (Type XHHW-2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eOutside Diameter:\u003c\/b\u003e 0.659 x 0.416 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-path-to-node=\"11,4,0\" data-index-in-node=\"0\"\u003eAllowable Ampacity:\u003c\/b\u003e 75 Amps @ 90°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,5,0\"\u003e\u003cb data-path-to-node=\"11,5,0\" data-index-in-node=\"0\"\u003eNet Weight:\u003c\/b\u003e 0.281 lbs\/ft (281 lbs per 1,000 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003ci data-path-to-node=\"12\" data-index-in-node=\"0\"\u003e*Data provided on this page is subject to change based on different manufacturers' variances.\u003cbr\u003e\u003cbr\u003e*Images are for reference only.\u003cbr\u003e\u003c\/i\u003e\u003c\/p\u003e","brand":"Global Cable and Wire","offers":[{"title":"Default Title","offer_id":52128031277339,"sku":"GCW1340","price":3.52,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/ChatGPTImage27abr2026_19_33_24.png?v=1777336416"},{"product_id":"8-8-8-copper-service-entrance-cable-seu","title":"8-8-8 Copper Service Entrance Cable SEU","description":"\u003cp data-path-to-node=\"2\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box. Minimum 25' to maximum 1000'.\u003c\/p\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3\"\u003eApplications:\u003c\/b\u003e Type SE, Style SEU Service Entrance Cable is a round and flat electrical cable used in all instances where service entrance cables are allowed. It is most often used to connect utility power to the meter base. This cable is suitable for wet and dry locations with temperatures not exceeding 90°C. The voltage rating of the electrical cable is 600 volts.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4\"\u003eConductor:\u003c\/b\u003e Annealed soft copper conductors.\u003c\/p\u003e\n\u003cp data-path-to-node=\"5\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5\"\u003eInsulated Phase Conductors (2 Conductors):\u003c\/b\u003e 8 AWG, 1-strand (solid) annealed soft copper equipped with cross-linked polyethylene (XLPE) Type XHHW-2 insulation. Rated for up to 90°C in wet or dry locations.\u003c\/p\u003e\n\u003cp data-path-to-node=\"6\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6\"\u003eEquipment Ground Conductor:\u003c\/b\u003e 8 AWG, 12-strand bare soft copper, applied as a concentric neutral ground around the insulated phase conductors.\u003c\/p\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7\"\u003eJacket:\u003c\/b\u003e Gray, sunlight-resistant polyvinyl chloride (PVC) jacket. This dielectrically strong outer layer is highly resistant to corrosion, abrasion, chemicals, and mechanical impact.\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8\"\u003eStandards:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003eASTM - All applicable standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003eUL Standard 44 for XHHW-2 conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003eUL Standard 83 for THHN\/THWN conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003eUL Standard 854 Service Entrance Cables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003eFederal Specification A-A-59544\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003eNFPA 70: National Electrical Code (2011 Edition)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003eRoHS \/ REACH Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"10\"\u003e\u003ci data-index-in-node=\"0\" data-path-to-node=\"10\"\u003eSpecifications:\u003c\/i\u003e*\u003c\/p\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,0,0\"\u003eSize AWG:\u003c\/b\u003e 8-8-8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,1,0\"\u003eConductor Material:\u003c\/b\u003e Annealed Soft Copper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,2,0\"\u003eInsulation Material:\u003c\/b\u003e XLPE (Type XHHW-2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,3,0\"\u003eOutside Diameter:\u003c\/b\u003e 0.587 x 0.380 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,4,0\"\u003eAllowable Ampacity:\u003c\/b\u003e 60 Amps @ 90°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,5,0\"\u003eNet Weight:\u003c\/b\u003e 0.211 lbs\/ft (211 lbs per 1,000 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003ci data-index-in-node=\"0\" data-path-to-node=\"12\"\u003e*Data provided on this page is subject to change based on different manufacturers' variances.\u003cbr\u003e\u003cbr\u003e *Images are for reference only.\u003cbr\u003e\u003c\/i\u003e\u003c\/p\u003e","brand":"Global Cable and Wire","offers":[{"title":"Default Title","offer_id":52128034816283,"sku":"GCW1341","price":2.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/files\/ChatGPTImage27abr2026_19_33_24.png?v=1777336416"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/9683\/8683\/collections\/ChatGPTImage27abr2026_19_33_24.png?v=1777337095","url":"https:\/\/www.globalcablewire.com\/collections\/copper-seu-wire.oembed","provider":"Global Cable and Wire","version":"1.0","type":"link"}